DVI/RGB Output
The DVI and RGB outputs (#12, #15 and #16) can output signals in following formats:
- VGA
- SVGA
- XGA
- SXGA-
- SXGA
- SXGA+
- UXGA
- WXGA*
- WXGA
- WXGA+
- WSXGA+
- 720p
- 1080p
- WUXGA
The "Auto resolution" function is activated by default. In this mode the Visualizer continuously checks
which devices are connected to the RGB (#12 and #16) and DVI output (#15) and automatically sets the
optimal output mode for each connected device separately.
the possible resolution, if the connected units or the cables* are not "Plug and Play" compatible. If the
Visualizer can not detect the resolution of the connected device, the output is set to the default of SXGA-
/60Hz.
(*Cables with plug and play compatibility must have a 15-pin plug on both ends with all pins connected).
If you can not use the "Auto resolution" function, you can select the output mode manually in the on-screen
menu of the Visualizer (see page 16).
In order to achieve the best picture quality you must set the outputs of the Visualizer to match the native
resolution of your display unit (e.g. LCD or DLP projector or monitor).
Important: What matters is the native resolution of the projector or monitor, not the maximum resolution that
it can display (in compressed mode). The native resolution is the actual number of pixels of the built-in LCD
display or DLP chip of a projector or monitor. Most LCD or DLP projectors can also display higher
resolutions than their native resolution, but only in compressed mode and with inferior picture quality.
Do NOT set the output of the Visualizer to a higher standard than the native resolution of your
display unit!
Do not set a higher refresh rate than your monitor or projector can display, otherwise the monitor or
projector can be damaged!
Follow the instructions in the user manual of the connected units.
Please note, if 4:3 and 16:9 or 16:10 resolutions are used simultaneously, the 4:3 display shows black bars
on top and bottom. This is necessary to ensure that all displays show the same image content.
DVI-I Port
The DVI Port (#15) supplies the digital and analog signal - DVI-I.
Pin 8
Pin 1
Pin 9
Pin 17
Pin 24
(4:3 - 640x480 pixels) at 60Hz
(4:3 - 800x600 pixels) at 60Hz
(4:3 - 1024x768 pixels) at 60Hz
(4:3 - 1280x960 pixels) at 60Hz - native image
(
5:4
- 1280x1024 pixels) at 60Hz
(4:3 - 1400x1050 pixels) at 60Hz
(4:3 - 1600x1200 pixels) at 60Hz
(16:10 - 1280x800 pixels) at 60Hz - native image
(16:9 Widescreen - 1360x768 pixels) at 60Hz
(16:9 Widescreen - 1440x900 pixels) at 60Hz
(16:10 Widescreen - 1680x1050 pixels) at 60Hz
(16:9 Widescreen HD/HDTV - 1280x720 pixels) at 50Hz or 60 Hz - native image
(16:9 Widescreen HD/HDTV - 1920x1080 pixels) at 30Hz, 50Hz or 60Hz
(16:10 Widescreen - 1920x1200 pixels) at 60Hz
1 - T.M.D.S. Data2-
2 - T.M.D.S. Data2+
3 - T.M.D.S. Data2/4 Shield
4 - T.M.D.S. Data4- (*)
C1
C2
5 - T.M.D.S. Data4+(*)
6 - DDC Clock
C3
C4
7 - DDC Data
C5
8 - Analog Vertical Sync
C1 - Analog Red
C4 - Analog Horizontal Sync
C5 - Analog Ground
(analog R, G & B return)
Choosing the Correct Output Mode
Please note that the Visualizer can not check
9 - T.M.D.S. Data1-
10 - T.M.D.S. Data1+
11 - T.M.D.S. Data1/3 Shield
12 - T.M.D.S. Data3- (*)
13 - T.M.D.S. Data3+ (*)
14 - +5V Power
15 - Ground (return for +5V,
HSync and Vsync)
16 - Hot Plug Detect
C2 - Analog Green
14
17 - T.M.D.S. Data0-
18 - T.M.D.S. Data0+
18 - T.M.D.S. Data0+
19 - T.M.D.S. Data0/5 Shield
20 - T.M.D.S. Data5- (*)
21 - T.M.D.S. Data5+ (*)
22 - T.M.D.S. Clock+
23 - T.M.D.S. Clock-
24 - Analog Vertical Sync
C3 - Analog Blue
m