Herunterladen Inhalt Inhalt Diese Seite drucken

Choosing Appropriate Connection Cables - Omnitronic B-600 Bedienungsanleitung

B-serie endstufe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection Speaker socket

Choosing appropriate connection cables

The speaker system must only be connected via a sufficiently dimensioned cable. Too thin cables lead to
cable heatup or enormous power loss and loss in sound quality.
For all speaker systems up to 400 Watts, we recommend a cable diameter of 2.5 mm², for all other speaker
cables 4 mm².
A high damping factor of your amplifier supplies a clear sound reproduction. Unnecessarily long and thin
cables will influence the damping factor and thus the low frequencies in a negative way. In order to
safeguard good sound quality, the damping factor should lie around 50. The longer a cable has to be, the
thicker it should be.
In this respect, a damping factor of 200 will be reduced to 47 (8 ohms) when using a 10 m long, 2.5 mm²
speaker cable. The power loss at 8 ohms is 1.63 %, at 4 ohms 3.25 % and at 2 ohms even 6.5 %.
The maximum cable length is 30 meters!
Installing the speaker cables
Connect the speaker systems among each other using the inputs and outputs. Connect the cable of the first
speaker system with the Speaker socket Output CH-1 and Output CH-2 of the amplifier. The signal will be
transmitted to the individual speaker systems.
Always treat the cables carefully and protect them from damages during transportation.
Install the cables always in a structured way and protect them from damage.
The cables must be installed in a way that no person can stumble over them. Always fix the cables with an
appropriate tape.
Both cables should be of the same kind.
Both cables should have the same length.
Both cables should be installed directly (no loops, S-shaped overlengths)
Always install the cables far away from power cables (never closely parallel)
Never put heavy objects like speaker systems, flightcased etc. on cables.
Never wind up cables tightly around the elbow, but rather sleek with an interior diameter of 20 to 30 cm.
Switch adjustments
Ground lift switch:
This switch allows the signal ground or chassis ground to be separated in case of a ground conflict. For
highest safety of the equipment, it is recommended to keep the Ground lift switch in the GND FLOATING
position. In case of a ground conflict please set the Ground lift switch to GND LIFT.
24/28
00039814.DOC, Version 1.0

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

B-1000B-1300B-2000B-3600

Inhaltsverzeichnis