2.1

































EN-12
System-specific parameters
For heat pumps with 2 compressors, this sets the external
temperature below which preparation of the swimming pool water
is carried out with 2 compressors.
The hysteresis of the swimming pool water set temperature forms
the neutral zone below which a swimming pool requirement
occurs.
Sets the desired swimming pool temperature.
Sets the desired swimming pool temperature with parallel cooling
operation.
Sets whether the waste heat recovery during cooling is dependent
on the switching status of the thermostat or in continuous
operation.
Sets the time programs for blocking swimming pool water
preparation.
Sets the times for the swimming pool block.
For each week day, it is possible to select whether Time1, Time2,
no time or both times are active for a block. Blocks that exceed a
week day are activated or deactivated at the end of each day
accordingly.
Sets the time programs for the prioritisation of swimming pool
water preparation.
Sets the start time for the prioritisation of swimming pool water
preparation.
Sets the desired number of hours of the prioritisation of the
swimming pool water preparation.
For each week day, it is possible to select whether prioritisation is
desired at the set start time.
These settings have to be made pursuant to the system
hydraulics.
Should the auxiliary circulating pump operate during heating
operation?
Should the auxiliary circulating pump operate during the cooling
operation?
Should the auxiliary circulating pump operate during domestic hot
water preparation?
Should the auxiliary circulating pump operate during swimming
pool water preparation?
Should the auxiliary circulating pump operate in the event of a
request by the 2nd heat generator?
Is it desirable that the heat circulating pump switches on and off as
required? If optimisation is switched off "NO", the heat circulating
pump is run in continuous operation.
Setting the flow time of the secondary pump before the
compressor starts.
Setting the switch off time of the secondary pump after the
compressor is switched off.
Should the M11 primary pump be running during the passive
cooling function?
Should the M13 heating pump be running during the passive
cooling function?
The language for menu navigation can be selected from the
available languages. The desired language can be selected by
pressing the ENTER button. The selection is finalised by pressing
the ESC button. Additional languages are available from the after-
sales service via Smart Key.
Setting range
-30 ... -25 °C ... 35 (10)
0.0 ... 0.5K ... 10.5
5 ... 25 °C ... 60
5 ... 25 °C ... 60
No / Yes
00:00 ... 23:59
00:00 ... 23:59
N / T1 / T2 / Y
00:00 ... 23:59
1 hours... 10
N / Y
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
Yes/ No
10 ... 60s ... 420
0 ... 5s ... 420
No / Yes
No / Yes