2.1






































EN-8
System-specific parameters
Temperature difference between cylinder-renewable and flow
temperature that must be overshot if the HP is to be blocked when
a heating request is pending
Comfort:A renewable heating block is only active when the
temperature in the renewable cylinder is higher than the current
return set temperature minus hysteresis.
Energy-optimised: A renewable heating block is independent of
the return set temperature.
Temperature difference between cylinder-renewable and domestic
hot water temperature that must be overshot if the HP is to be
blocked when a domestic hot water request is pending.
Temperature of the cylinder-renewable that must be overshot if the
HP is to be blocked when a swimming pool water request is
pending
Temperature difference between the collector and the cylinder at
which charging is activated
Maximum cylinder temperature
In areas with very hard water, it is advisable to lower the cylinder
temperature.
Before the stagnation temperature is reached, the maximum
cylinder temperature is raised by 5K in order to cool the collector
through heat loss in the cylinder and the pipes.
Maximum brine temperature up until which regeneration should
take place via solar
Advisable if the collector field is shaded
Nominal volume flow in the collector circuit
Is monoethylene or propylene glycol ad-mixed?
Proportion of glycol in the solar collector fluid (as a percentage)
Current errors from the solar function can be reset here
Current errors from the solar function can be reset here
The following heating control options can be selected for heating
circuit 1:
Return
temperature
control
temperature and the set heating curve
Return temperature control via a fixed-setpoint
Return temperature control based on the room temperature in
a reference room
The heating curve end point should be set according to the design
of the heat pump heating system. This should be done by entering
the maximum return set temperature, which is the product of the
maximum calculated flow temperature minus the temperature
difference in the heating system (spread).
Sets the desired return set temperature when fixed-setpoint
control is selected
Setting of which temperature sensor is used for measuring the
room temperature.
Sets the desired room set temperature and I ratio when room
temperature control is selected
External temperature
based
on
the
external
15.0 ... 20.0 °C ... 30.0
Setting range
2 ... 10K... 20
Comfort / energy-opt.
2 ... 5K ... 50
10 ...35 °C ... 50
1 ...6K ... 30
30 ... 85 °C ... 95
No / Yes
0 ... 22 °C ... 65
No / Yes
0.0 l/min ... 10.0
Propylene /
Monoethylene
0 / 10 / 20 / 30 / 40 %
No / Yes
No / Yes
fixed-setpoint
Room temperature
20 ...30 °C ... 70
min. setpoint temp.
... 40 °C ... 60
R13 / smart-RTC
001 ... 060 ... 999