2.1





































EN-10
System-specific parameters
The heating curve end point should be set according to the design
of the heat pump heating system. This should be done by entering
the maximum flow or return temperature depending on the position
of the sensor.
Parallel adjustment of the heating curve that is set for the 
2nd/3rd heating circuit. By pressing the arrow buttons once, the
heating curve is shifted by 1K upwards (hotter) or downwards
(colder).
Sets the desired set temperature when fixed-setpoint control is
selected
Different maximum temperatures are permissible for panel and
radiator heating systems. The upper limit of the set temperature
can be set between 25 °C and 70 °C.
The return set temperature hysteresis forms the neutral zone for
operation of the heat pump.
The runtime between the OPEN and CLOSED end positions
varies according to the mixer used. The mixer runtime should be
adjusted to ensure optimum temperature control.
Settings to lower the heating characteristic curve of heating circuit
2/3.
Sets the times at which a lower should occur for 
heating circuit 2/3.
Sets the temperature at which the heating characteristic curve 
of the 2nd/3rd heating circuit should be lowered during a lower.
For each week day, it is possible to select whether Time1, Time2,
no time or both times are active when the temperature is lowered.
Operations to lower the temperature that exceed a week day are
activated or deactivated at the end of each day accordingly.
Settings to raise the heating characteristic curve of heating circuit
2/3.
Sets the times at which a raise should occur in 
heating circuit 2/3.
Sets the temperature at which the heating characteristic curve 
of heating circuit 2/3 should be raised by.
For each week day, it is possible to select whether Time1, Time2,
no time or both times are active when the temperature is raised.
Operations to raise the temperature that exceed a week day are
activated or deactivated at the end of each day accordingly.
Sets the room set temperature for silent cooling. The actual value
is measured by room climate station 1/2.
Raises the minimum permissible flow temperature as calculated
from the measured values of room climate station 1/2. A raised
value reduces the risk of condensate forming.
Sets the time programs for dynamic cooling.
Sets the times during which dynamic cooling is blocked.
For each week day, it is possible to select whether Time1, Time2,
no time or both times are active for a block. Blocks that exceed a
week day are activated or deactivated at the end of each day
accordingly.
Setting to specify whether a second chiller is to be used in the
system.
Sets the external temperature below which cooling with reversible
brine HP or passive cooling is interrupted.
If the current return set temperature for passive cooling minus
hysteresis is greater than the current brine temperature then
passive cooling occurs.
Setting range
20 ... 30 °C ... 70
Indicator bar
min. setpoint temp.
... 40 °C ... 60
30 ... 50 °C ... 70
0.5 ... 2.0K ... 5.0
1 ... 4 minutes ... 6
00:00 ... 23:59
00:00 ... 23:59
0K ... 19
N / T1 / T2 / Y
00:00 ... 23:59
00:00 ... 23:59
0K ... 19
N / T1 / T2 / Y
15.0 ...20.0 °C ... 30.0
1.5 ...3.5K ... 5.0
00:00 ... 23:59
00:00 ... 23:59
N / T1 / T2 / Y
No / Yes
-20 ... 3 °C ... 35
0.1 ... 2.0K ... 9.9