Configuration
































System-specific parameters
For heat pumps with 2 compressors, this sets the external
temperature below which domestic hot water preparation is carried
out with 2 compressors.
The hysteresis of the domestic hot water set temperature forms
the neutral zone below which a request for domestic hot water will
be issued.
Does hydraulic isolation of the cooling circuit and the domestic hot
water circuit allow for parallel operation of cooling and domestic
hot water?
Sets the desired domestic hot water set temperature.
Sets the desired domestic hot water set temperature which is to be
reached during parallel operation.
When a domestic hot water request is pending during heating
operation, heat pumps with an additional heat exchanger allow the
user to select whether domestic hot water preparation should have
priority (convenience) or it should continue to take place parallel to
heating operation (energy-optimised).
Sets whether the existing flange heater is also to be used for
reheating. If set to "No", domestic hot water preparation only
occurs up to the current HP max. temperature (depending on the
heat source temperature).
Sets the time program for domestic hot water blocks
Sets the times in which domestic hot water preparation is blocked.
For each week day, it is possible to select whether Time1, Time2,
no time or both times are active for a block. Blocks that exceed a
week day are activated or deactivated at the end of each day
accordingly.
Sets the domestic hot water set temperature which should be
maintained even during a domestic hot water block.
To carry out a thermal disinfection, the domestic hot water is
heated up once to the desired temperature. The heating period is
terminated automatically when the set temperature is reached, at
12:00 p.m. or after 4 hours at the latest.
Sets the start time for the thermal disinfection.
Sets the desired domestic hot water set temperature which is to be
reached during thermal disinfection.
For each week day, it is possible to select whether thermal
disinfection is desired at the set start time.
The circulation pump is started using a paddle flow switch, for
example. When the paddle flow switch returns to the original
position, the circulation pump operates for the duration of the set
time.
The circulation pump is controlled by a timer function.
Sets the times at which the circulation pump is to be activated.
For each week day, it is possible to select whether Time1, Time2,
no time or both times are active for the circulation pump.
Operations that exceed a week day are activated or deactivated at
the end of each day accordingly.
By setting Reset to Yes, the maximum calculated domestic hot
water temperatures in HP operation are reset to a value of 65 °C.
The setting is automatically reset to "No".
2.1
Setting range
-30 ... -25 °C ... 35 (10)
2 ...7K ... 15
No / Yes
30 ... 50 °C ... 85
30 ... 60 °C ... 85
Comfort / Energy-opt.
No / Yes
00:00 ... 23:59
00:00 ... 23:59
N / T1 / T2 / Y
0 ... 10 ...
Domestic hot water Set
temp.
00:00 ... 23:59
60 °C ... 85
N / Y
1 ... 5 minutes ... 15
00:00 ... 23:59
00:00 ... 23:59
N / T1 / T2 / Y
No / Yes
EN-11