Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Elements; Operation; Control With Electronic Overload Protection And Built-In Control Elements - Pfaff StandardLine BGV D8 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electric wire rope winch BETA SL
E nglish

3.10 Operating Elements:

The operating elements (operating places) have to be in-
stalled in such a way that the entire load distance can be
overlooked from the operator's position.
Push buttons have to be located in reasonable position.
Connection, protective measures and safety pre-
cautions have to be effected according to local,
national and international regulations.
Before taking into operation, check:
correct polarity, turning direction, placement of order devices
protective conductor system
insulation resistance
overload protection adjustment (if existing)
function
4

Operation

Before taking into operation please turn on the main switch. The required direction is to be initiated by
pressing the respective push-button Up
During operation, the operator always has to observe the load, the room below and above the load and
the load carrying device. For safety instructions see 1.3 page 19
In case of occurring faults, immediately stop operation and eliminate the fault. Always pay attention to
correct turning direction of the rope drum. Never coil up the rope incorrectly.
When overload protection is effective, reduce the load.
In case of danger operate the Emergency-Stop switch.
4.1 Electric control with integrated operating elements

4.2 Control with electronic overload protection and built-in control elements

Überlast
Overload
Auf
Up
Ab
Down
Not-Aus
Emergency-stop
When leaving the control place, secure the danger area under the load. After use,
turn off the main switch and (if necessary) close the main switch with a lock.
technische Änderungen vorbehalten
- Down .
At each operating point, a quick and easy accessible emergency
stop device shall be provided.
Where necessary, provide additional devices for emergency stop.
e.g. nearby unprotected winches.
When overload is effective reduce the load
The electronic overload protection is adjusted and is effective at 100
to 110 % of the nominal load.
The overload protection system must be classified in accordance
I
with DIN EN 13849-1 for classification in category 2 PLc.
0
In case the overload protection system is effective, the system
switches into a safe condition. Lifting the load is no longer possible.
Hauptschalter
The resetting of the overload protection function is carried out by
Main switch
pressing the function button "Down"
design changes under reserve
04.01.401/1000
changements techniques sous réserve
26

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Pfaff StandardLine BGV D8

Diese Anleitung auch für:

Sl0Sl3Sl1Sl2

Inhaltsverzeichnis