Herunterladen Inhalt Inhalt Diese Seite drucken

Electric Controls; Emergency-Stop Switch - Pfaff StandardLine BGV D8 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electric wire rope winch BETA SL
E nglish
3.2 Indication EMV
The electric wire rope winch with control is designed for industry.
The winch has to be switched at max. 5 times/minute to accomplish the standards for electromagnetic
emissions EN DIN 50081-2).
EMV proceedings (filter) have to be carried out if the winch has to be switched more than 5 times/mi-
nute or by using other electronic switching circuits (on site or delivered as option).
3.3 Connection to three-phase network
The connecting plan integrated in the motor terminal box has to be observed.
3.3.1
Motor-connection-Junction plate, three-phase current, 1 speed
Star connection
Y

3.4 Electric controls

Electric control with mounted-in revers-
ing contactor, thermal motor protection,
main switch and integrated operating
elements
Electric control with mounted-in revers-
ing contactor, thermal motor protection,
main switch and integrated operating
elements
Electric control with mounted-in re-
versing contactor, thermal motor protec-
tion, main switch, main contactor and
electronic overload protection*
*
Wire rope winches with a load of 1000 kg and more have to be equipped with an overload protection
Pfaff-silberblau contactor control is designed for:
Winches with 1 wire rope speed and AC connection
f=50 Hz: 380÷420 V
Type of protection IP54
Operating voltage 42 V; 50 Hz
Attention
When connecting the winch to a three-phase network U=440÷460V,
the bridge of the transformer has to be switched from A÷B to B÷C!
Winches with 1 wire rope speed for single-phase AC
f=50 Hz: 220÷240 V single-phase AC
Type of protection IP54
Operating voltage 24 V, 50 Hz
For supply of the control current circuit, a transformer with galvanic separation must be used (pro-
vided in Pfaff-silberblau controls).
In any case, an easily accessible emergency stop push-button (switch) has to be provided. (provided
in Pfaff-silberblau controls, different designs)

3.5 Emergency-stop switch

An emergency shut-off switch must be located at each control point and must be quickly and easily ac-
cessible. Where necessary, there must also be an additional device for emergency stop, like f. e
around an unprotected winch.
technische Änderungen vorbehalten
W2
U2
V2
U1
V1
W1
L1
L2
L3
Mat.-no.
Control
31610600
400 v
192008316
230 V
31610611
400 V
design changes under reserve
04.01.401/1000
f = 50 Hz:
driving power < 3,0 kW
voltage: 380 ÷ 420 V
Wiring diagram No.
L04.01.401/0000-1700 40063758; 31140006;
L04.01.401/0001-1900 31140015
L04.01.401/0000-1740 40062993; 40062996
Transformator
transformer
380-420V 440-460V
changements techniques sous réserve
Mat.-no.
Winch
40062946; 40062989
40062990;
380-420V 440-460V
23

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Pfaff StandardLine BGV D8

Diese Anleitung auch für:

Sl0Sl3Sl1Sl2

Inhaltsverzeichnis