Electric wire rope winch BETA SL
E nglish
2.5 Rope coiling
rope coiling - right
Standard version
2.6 Wire rope attachment -
ATTENTION:
In standard design, the winch has two wire rope attachments. The rope may optionally be fixed on left or
right drum flange.
Pay attentions to correct polarity of the actuating motor.
Insert the rope in consideration of
winding direction
Tighten clamping screws
rope Ø
clamping screws
no. of screws
Tightening torque [Nm]
The technical data concerning minimum tensile strength respective wire rope type are to be ac-
cording to name plate respective information's in operating manual.
When the load is unguided, in special when hanging on a single rope, the right rope must be
chosen in accordance with the rope twisting behaviour.
In accordance to the rope diameter respective rope length, you must choose a special non-
twisting or non-rotating rope.
Calculate the rope length in such a way that at least 3 full turns of rope remain on the drum in
lowest load position. Observe max. rope length.
3

Electric Installation

Works on the electric installation may only be effected:
with cleared power supply
by trained and qualified electricians
Observe the regulations and standards of electric engineering.
In Germany, VDE regulations do apply.
3.1 Mounting indication for contactor control
The contactor control must only be mounted with vertical standing contactor.
Max. sloping position 22,5°.
For controlling the winch, an electric control is required
The respective standard electric control fitted to the electric wire rope winch is de-
livered with the winch.
technische Änderungen vorbehalten
90°
180°
SL0
.
Tightening torque for clamping screws 
4
M 5
2
4,8
design changes under reserve
rope coiling - left
270°
SL1 – SL3
1
3
2
4
6
M 6
2
8,5
changements techniques sous réserve
04.01.401/1000
270°
90°
Insert the rope  in consid-
eration of rope winding direc-
tion into the wire rope attach-
ment bore 
Tighten clamping screw 
 The end of the rope  has to
look out from the wire rope
attachment 
9
12
M 8
M 12
2
2
20
60
180°
22