MOUNTNING AND CONNECTIONS

1
First, connect the LEDs to the screw terminals CH1 to CH3 as well as
the common positive pole. The total load by the LEDs must not
exceed 6 A; otherwise the control unit will be damaged.
CH1 = negative pole for the red LEDs
CH2 = negative pole for the green LEDs
CH3 = negative pole for the blue LEDs
+ = common positive pole
2
For power supply, a matching power supply unit will be required (min.
12 V, max. 24 V). There are screw terminals (V+ and V-) provided for
this. The power supply unit must provide the current required for
operating the LEDs plus a supply current of 100 mA for the control
unit.
V+ = positive pole
V- = negative pole