General
UKV has several different areas of use.
UKV can be used with external control of the heating
system. The heat pump then charges UKV with floating
or fixed condensing. The external control function con-
trols the heat distribution from UKV to the consumer.
If the flow to the heating system can be throttled with
radiator thermostats for example, install a UKV as an
intermediate tank. This ensures a secure flow for the
heat pump.
UKV also allows a greater flow to the heating system
than across the heat pump.
In some installations, so-called heat spikes occur as a
result of movements during temperature changes. To
eliminate temporary temperature changes, and thereby
prevent heat spikes, install a UKV after the heating
installation.
UKV can also be used to increase the system volume
and prevent malfunctions.
This appliance can be used by children aged from 8 years and above and per-
sons with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concer-
ning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
Rights to make any design or technical modifications are reserved.
©NIBE 2014.
INSTALLATION INSTRUCTIONS
UKV 100
Assembly
UKV is installed vertically suspended on the wall. First
install the supplied mounting bracket on the wall, then
mount UKV on the bracket.