Herunterladen Diese Seite drucken

Flow Diagram - HANSGROHE Raindance Showerpipe 27235000 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für Raindance Showerpipe 27235000:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Safety Function (see page 19)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Maintenance (see page 22)
• The mixer is equipped with check valves.
The check valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
Dimensions (see page 20)
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not cor-
respond with temperature set
Temperature regulation not possible
Instantaneous heater didn't work with
thermostat
English
Cause
- Supply pressure inadequate
- Filters are dirty (#96922000)
- filter insert shower dirty
(#97708000)
- Shower filter seal dirty
(#94246000)
- Backflow preventers dirty or leaking - Clean backflow preventers, ex-
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't
removed
Assembly see page 14

Flow diagram

(see page 21)
overhead shower
Hand shower
Operation (see page 24)
Cleaning (see page 25) and en-
closed brochure
Spare parts (see page 28)
Special accessories (order as an
extra)
tile-matching-disk chrome plated
#98681000
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filter in front of the mixer and
on the MTC-thermo cartridge
- Clean filter insert between shower
and hose
- Clean filter seal between shower
and hose
change if necessary
- Adjust thermostat
- Increase hot water temperature to
42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
5

Werbung

loading