Installation

Plumbing

Cold water
Hot water
Connection must be made to the water supply
via a stopcock which conforms to current
local and national regulations. This work must
be carried out by an authorised person.
Water Supply (Water Fittings) Regulations
1999 and Water Byelaws 2000, Scotland
The Type A air gap fitted to the machine pro-
vides Category 5 protection thereby enabling
connection to mains water. The air gap is lo-
cated upstream of the detergent box and to
provide protection against the possibility of
backflow of cleaning agents the machine is
supplied with 3 double check valves which
should be connected to the inlet hoses.
See the installation diagram for instructions
on connection to the water supply and for
drainage.
The inlet pressure hoses supplied with the
machine must be used for connection to the
water supply.
To ensure the hot water inlet hose (marked
90°C) lasts for many years it is advised not to
use it on a hot water connection supplying wa-
ter hotter than 70°C.
If replacing inlet hoses only use a hose able
to withstand a burst pressure of at least 70
bar, and a water temperature of at least 90°C.
58
Cold water
Hard water
This also applies to all connection parts. Use
spare parts recommended by the manufactu-
rer.
A water pressure flow rate of at least 1 bar,
static water pressure max. 10 bar is essential
to ensure smooth operation of this machine.
Water taken into the machine must not ex-
ceed a temperature of 70°C.
Connection to cold water only
-See enclosed Installation Diagram.-