Table 4: Diagnostic parameters, outputs

Page 10 of 17
Use
The diagnostic value for the correction of errors remains until a valid
minute pause is found.
0000:
No error
FE01: Undefined value for the input „Aufruf"
FE02: Pulse lengths outside the tolerance
FE03: Pause lengths outside the tolerance
FE04: No minute pause found
FE05: Permanent signal at the input
FE06: Incorrect parity in the DCF77 time telegram
FE07: Time inconsistent, two consecutive DCF77 time telegrams are
not different by 1 minute
FE08: Error in setting the time of day in the S7-CPU
Length of the last pulse outside the tolerance, indicated in multiples of
10ms.
Length of the last pause outside the tolerance, indicated in multiples of
10ms.
Version 3.0
Document order No.: 2XV9450-1AR33