Installing and connecting WLAN antennas

General

If the Fronius Datamanager is equipped with WLAN, the WLAN antenna must be installed
either inside or outside the inverter, depending on which inverter is being used.
IMPORTANT! Always follow the relevant operating instructions when opening an inverter.
Observe the safety guidelines.
Fronius IG, Fro-
nius IG Plus, Fro-
nius IG Plus V,
Fronius CL: In-
stalling and con-
necting antennas
82
2
1
0,8 - 1,1 Nm
Use the double-sided adhesive tape to
1
fasten the mounting bracket to the out-
side of the inverter housing or, if sui-
table for the antenna cable, secure it in
a position near the inverter
IMPORTANT! The double-sided adhe-
sive tape only reaches its maximum
bond strength after 24 hours.
IMPORTANT! The mounting bracket
may not be screwed to the inverter
housing.
It may however be fitted in a nearby po-
sition. The relevant screws are not in-
cluded in the scope of delivery and
must be selected by the installer.
Connect the antenna cable to Fronius
2
Datamanager
Run the antenna cable out through the
3
"DATCOM Opening" on the inverter
If possible, secure the cable with a
4
strain relief device
Close or seal the "DATCOM Opening"
5
in accordance with the inverter opera-
ting instructions