9 /
34 • GAFM-II-10.12
INSERTING
battery
compartment
safety screw
DE-AERATING
FLUIDWAYS
The
insert battery is delivered with a partial charge
We recommend
BATTERY
„D" MAINTENANCE + CARE).
a.
To place the battery in the device, first loosen
screw
until the screw head corresponds with the outer surface of the device's housing.
Stop if there is noticeable resistance, do not use force,
battery compartment.
b.
Now push the battery into the battery compartment (see illustration) with contacts
first and inscription
clicks into place.
Now fasten the battery securing screw by turning it clockwise;
c.
is noticeable resistance.
d.
This
operation is necessary to prevent the battery from falling out.
means
rosive acid might escape.
e.
The FlowMarker is
If the battery is empty it has to be charged* with the battery charger,
TERY" first flashes, afterwards it lights up permanently.
MAINTENACE AND CARE „Charging the battery".)
In this way the user can recognize early on that a recharging of the battery is impending,
one can therefore usually performing its current investigation until to its final end.
If the
red LED lights up permanently,
imately
2 - 6 minutes
the unit turns off itself completely to protect the battery against deep discharge.
NOTE:
A short flash of all LED's happens when switching the power
signal monitoring. In these cases, the brief flash of the red LED is no sign of a battery
defect.
For optimum performance, de-aerate the fluid ways in the device
a.
Activate and heat up the
LED will flash.
b.
The heating-up takes about 30 seconds when the device is cold.
heat-up
(green
hold the device vertically, with its nozzle or application tube pointing up. Press the
fog button shortly to start the fog production (white LED lights up) for about 45 se-
conds, until the fog comes out evenly. A pushing of the blue button stops the fog
production than.
De-aerating can only be carried out in upward direction!
to entirely charge the battery
(see illustration) with a screwdriver counter-clockwise just one or two turns
(
)
LONG
™
pointing up
let the lead-acid battery fall out of the device
now ready for operation.
there is a
for producing fog depending on the battery-conditions. After that,
FlowMarker
LED "Ready"
lights up permanently!)
for the initial test of the device.
before continuous use (see also chapter
the battery compartment safety
this may damage the
until the battery audibly and noticeably
again, stop if there
as it might break and cor-
the red LED "BAT-
(*See for this section „D"
remaining battery capacity
ON
after every refill.
®
by pushing the blue fog button, the green
After complete
By no
of approx-
or OFF, it is a