Adr. Typ Funkt. Name
100 U
3 / 4
OUTP0WER0
101 U
3 / 4
OUTP0WER1
102 U
3 / 4
OUTP0WER2
103 U
3 / 4
BATTCAP
104 S
3 / 4
INVOLT0
105 S
3 / 4
INVOLT1
106 S
3 / 4
INVOLT2
107 S
3 / 4
TEMPDEG
108 S
3 / 4
AUTONOMTIME
STATUS (e. g. UPS normal = "4",
109 U
3 / 4
Powerfail = "12", Battery test running =
110 S
3 / 4
BATTVOLT
"68", Bypass = "5" )
111 U
3 / 4
INFREQ0
112 U
3 / 4
INFREQ1
113 U
3 / 4
INFREQ2
114 U
3 / 4
CNT_PF
115 U
3 / 4
Alarm Battery Bad
116 U
3 / 4
Alarm: On Battery
117 U
3 / 4
Alarm: Battery Low
118 U
3 / 4
Alarm: Battery Depleted
119 U
3 / 4
Alarm: Over temperature
120 U
3 / 4
Alarm: Input Bad
121 U
3 / 4
Alarm: Output Bad
122 U
3 / 4
Alarm: Output Overload
123 U
3 / 4
Alarm: On Bypass
124 U
3 / 4
Alarm: Bypass Bad
125 U
3 / 4
Alarm: Output Off as requested.
126 U
3 / 4
Alarm: UPS Off as requested.
127 U
3 / 4
Alarm: Charger Failed
128 U
3 / 4
Alarm: UPS Output Off
129 U
3 / 4
Alarm: UPS System Off
130 U
3 / 4
Alarm: Fan Failure
131 U
3 / 4
Alarm: fuse failure
132 U
3 / 4
Alarm: general fault
133 U
3 / 4
Alarm: diagnose test failed
134 U
3 / 4
Alarm: communication lost
135 U
3 / 4
Alarm: awaiting power
136 U
3 / 4
Alarm: shutdown pending
137 U
3 / 4
Alarm: shutdown imminent
138 U
3 / 4
Alarm: test in progress
139 U
3 / 4
AUX Port 1
140 U
3 / 4
AUX Port 2
141 U
3 / 4
AUX Port 3
142 U
3 / 4
AUX Port 4
143 U
3 / 4
Sensormanager/SMTCOM sensor 1
144 U
3 / 4
Sensormanager/SMTHCOM sensor 2
145 U
3 / 4
Sensormanager sensor 3
146 U
3 / 4
Sensormanager sensor 4
147 U
3 / 4
Sensormanager sensor 5
148 U
3 / 4
Sensormanager sensor 6
149 U
3 / 4
Sensormanager sensor 7
150 U
3 / 4
Sensormanager sensor 8
Copyright of the European Union is effective (Copyright EU) (c) 2010 ONLINE USV-Systeme AG, Munich, Germany, All rights reserved
Seite 14 von 26
TEL +49(89)242399010 -
info@online-usv.de
Beschreibung
Outpower Phase 1 %
Outpower Phase 2 %
Outpower Phase 3 %
Battery Capacity %
Input Voltage Phase 1 V
Input Voltage Phase 2 V
Input Voltage Phase 3 V
Temperature C°
Autonomy Time minutes
UPS Status (ASCII HEX)
Battery Voltage V
Please note UPSMAN status bytes
Input Frequency Hz Phase 1
table below
Input Frequency Hz Phase 2
Input Frequency Hz Phase 3
Powerfail Counter
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active (high); 0 = not active (low)
1 = active (high); 0 = not active (low)
1 = active (high); 0 = not active (low)
1 = active (high); 0 = not active (low)
Analog value
Analog value
Analog value
Analog value
Analog value
Analog value
Analog value
Analog value
-
www.online-usv.de
Datum: 2010-11-26
Länge
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis