Herunterladen Inhalt Inhalt Diese Seite drucken

Control Panel - AL-KO Robolinho 100 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für Robolinho 100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
To avoid damage when mowing, make sure
that the boundary cable is in direct contact
with the ground at all points when you are lay-
ing it.
If there are places where the boundary cable
is not in direct contact with the ground, secure
these with an additional lawn peg
WARNING!
Damage to the boundary cable!
Do not scarify the lawn in the area on eit-
her side of where the boundary cable is
laid.
Spare loops of cable
You should incorporate spare loops of cable
(12-1) at regular intervals in order to allow the
base station to be repositioned or the mowing
area to be extended even after the mowing area
has been laid out. To do this, guide the boundary
cable around a lawn peg, return to the previous
lawn peg, then continue as shown, securing with
another lawn peg.
Select the number of spare cable loops ac-
cording to your own judgement.
Laying options
The boundary cable can be laid on the lawn (8-1)
and as much as 10 cm under the turf (8-2). Have
your dealer carry out the laying under the turf on
your behalf.
If necessary, you can also combine both me-
thods.
Laying the cable around obstacles
When laying the cable around obstacles, maintain
the distances shown in the illustration (12).
If there is a distance of 0 cm between the cables, it
is possible for the cable to be driven over. In most
cases, the best solution.
When the distance is at least 30 cm, the
Robolinho interprets the distance as a path and
moves around the obstacle.
When laying the boundary cable in walkways
(12-4), it is necessary to maintain the minimum
distances from obstacles and the minimum pas-

CONTROL PANEL

3-1
The [LCD display] displays the current status or the selected menu.
Pressing the [STOP key] stops the Robolinho and the cutting blades within 2 se-
3-2
conds.
26
sage width specified in the illustration (12), other-
wise the Robolinho will not be able to operate cor-
rectly.
Crossovers in the boundary cable lead
to malfunctions because the inside and
outside parts are swapped over.
Connecting the boundary cable to the base
station
1
Remove the insulation from the boundary ca-
ble (6-2) after laying the cable and connect to
the spring terminals.
Connecting the low-voltage cables to the
transformer
1
Unscrew the screws with a screwdriver (6-3)
and connect the low-voltage cables to the
transformer (6-5).
The cables can be connected are requi-
red, there is no need to observe a parti-
cular polarity.
2
Insert the mains plug of the transformer into
the mains socket (6-4).
Opening the base station
The cover (7-3) can be opened for checking the
LED indicators for troubleshooting (in case of a
fault).
Checking the connection
Once the cables have been connected, the LEDs
(7-1) and (7-2) must light up. If this is not the
case, pull out the mains plug and check if all plug
connections and cables are correctly seated; also
check them for damage.
Yellow LED (7-1)
lights up if the base station is connected to the
transformer and there is an electrical power
supply to the transformer.
flashes when the Robolinho is charging.
Green LED (7-2)
lights up when the boundary cable is laid cor-
rectly and the loop is OK.
flashes and then goes out if the loop of the
boundary cable is not OK.
Assembly
Robolinho
100
©

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis