Herunterladen Inhalt Inhalt Diese Seite drucken

Factory Setting - SSS Siedle S 851-0 Inbetriebnahmeanweisungen

Vorschau ausblenden Andere Handbücher für S 851-0:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Configuring the base station/Smart Gateway Mini

Factory setting

The base station must remain ener­
gized during the reset, otherwise a
correct reset cannot be performed.
When resetting the Smart Gateway
Mini (base station) this returns to the
as­delivered status:
• The PIN is reset to 0000;
• All registered cordless handsets are
deregistered;
• All app users are deactivated, con­
nection via the Siedle app for Smart
gateway Mini is no longer possible;
• If activated, the door call rerouting
/ Doormatic function are deactivated
again;
• The network settings of the base
station are reset;
• The user settings for the brows­
er­based user interface are reset;
• The bus configuration (i.e.
intercom contacts, switching func­
tions etc.) and the phonebook are
retained;
• The passwords for login at the
Smart Gateway Mini are reset.
102
Procedure:
1 Unplug the patch cable for the
In­Home bus at the base station.
2 Press the Prog. button at the base
station (e.g. using a straightened
paper clip or similar) and hold it
down until you have carried out the
following steps.
3 Plug the patch cable for the
In­Home bus back into the base
station.
4 When the Prog. LED flashes twice,
release the Prog. button.
5 The delete process has started, the
reset is in progress.
6 The Status LED on the front of
the base station flashes red/green to
indicate that the reset is complete.
7 Carry out a manual reset at the
base station.
Briefly disconnect the base
station from the power mains and
reconnect.
In-Home
Prog.
Line
LAN
Power

Quicklinks ausblenden: