14.3 Workplace requirements

The workplace has to fulfill the requirements.
The ground has to be even, in level and hard. It must be suitable at least to weight it with double
weight per square meter than the machines net weight.
The chosen workplace must have access to a suitable electric supply net hat complies with the
machines requirements.

14.4 Transport

The machine can be transported in package with a forklift.
The machine is very heavy. The machine shall be lifted from crate with a suitable lifting device only
that is certified to be able to carry the machines load.
The lifting and transportation of the machine must only be carried out by
qualified staff and must be carried out with appropriate equipment.
Note that lifting equipment used (crane, forklift, sling, etc.) must be in perfect condition.
To maneuver the machine in the packaging can also a pallet jack or a forklift be used.
Uncoated metal machine parts have been insulated with a greasy layer to inhibit corrosion.
This layer has to be removed. You can use standard solvents that do not damage the machine
surface.
14.5

Power supply

When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1. The electronic connection of the machine is designated for operation with a grounded power
socket!
2. The mains supply must be secured with 16A:
3. If the connector plug doesn't fit or if it is defect, only qualified electricians may modify or
re-new it!
4. The grounding wire should be held in green-yellow.
5. A damaged cable has to be exchanged immediately!
6. Check, whether the feeding voltage and the Hz comply to the required values of the
machine. A deviation of feeding voltage of ±5% is allowed (e.g.: a machine with working
voltage of 380V can work within a voltage bandwidth of 370 till 400V.
7. After connecting, check the right running direction!
8. Make sure that a possible extension cord is in good condition and suitable for the
transmission of power. An undersized cord reduces the transmission of power and heats up.
9. A damaged cable must be replaced immediately