Aircirculation Heater Phoenix 2.8
1. Delivery Checklist
1x air circulation heater PHOENIX 2.8
2x foot
2x chain with snap hook
2x V-hook
4x self tapping screw
4x locking washer
2. Technical data
Apparatus type:
Power supply:
Power:
Current:
Control range:
Protection category:
Protection class:
IMPORTANT:
Familiarise yourself with the instructions in this manual and the general safety and hazard notes
before installation. Keep this document in a safe place for future reference. If you have any doubts
about the safety of the apparatus, please consult a skilled person. When installing in a greenhouse,
please ensure that the electrical connections are made by a qualified person.
3. General
After unpacking and before using for the first time, ensure that the apparatus and all the accessories
are not damaged. In case of transport damage, please contact your distributor or the manufacturer
immediately. Keep packaging material (polybags, polystyrene, nails etc.) out of reach of children, since
such materials are hazardous.
The PHOENIX 2.8 electric air circulation heater is designed to heat greenhouses and winter gardens
uniformly, also saving energy. Its defining features include simple operation and minimum installation
space requirement. This apparatus is designed for connection to 230 V ~ / 50-60 Hz AC only. It must
be protected against heavy soiling and moisture. Any use other than that described above may
damage the apparatus and also carries risks of e.g. short circuits, fire, electric shock, etc. It is
imperative that the safety and installation instructions are followed.
PHOENIX 2.8
230 V ~ / 50-60 Hz
1000 / 1800 / 2800 W
13 A (max.)
0 – 26 ° C
I
IP X4
11