• Do not clean or store the machine unless it is completely cooled down.
• Do not move the machine while it is under operation. Unplug the machine when moving
the machine and hold it at the bottom.
• Do not operate the machine without ingredients to avoid overheated.
• Ensure the machine is in STANDBY mode and unplug it after use.

Grounding installation

This appliance is classified as protection class I
appliance and must be connected to a protective
ground. Grounding reduces the risk of electric
shock by providing an escape wire for the electric
Main parts of the machine
Digital control panel
current. This appliance is equipped with a cord
having a grounding wire with a grounding plug. The
plug must be plugged into an outlet that is properly
installed and grounded.

1. Power switch

(ON/ STANDBY): Press to
switch ON the machine; Press again to switch to
STANDBY mode
2. Speed control: Select and then press to the de-
sired speed.
( Low / Medium / High)
3. Timer: Select and then press to the desired time
(30s / 45s / 90s)
4. Pulse button
: Full speed impulse movement.
Press and hold to operate, re-
lease the button to stop.
5. Digital control display
6. Motor base
7. Control panel
8. Blade assembly
9. Jug
10. Jug lid
11. Cover cap
12. Protective cover