from a cold environment. Please wait
until the appliance has adjusted to the
temperature and is completely dry be-
fore operating it. The acclimatization
period depends on the temperature dif-
ference and the type and design of the
appliance. However, it should be at least
12 hours.
Connecting the power supply
Check that the rated voltage indicated
on the appliance matches the mains
voltage in your area. Connection to the
incorrect voltage will damage or destroy
the appliance.
Before switching on the appliance,
check that all cables and lines are prop-
erly fitted and undamaged. Make sure in
particular that there are no kinks in the
cables, that they are not pulled too
tightly around corners and that no ob-
jects are resting on them. Also make
sure that all plug connections are se-
curely inserted. Faulty shielding or wir-
ing poses a health hazard (electric
shock) and can destroy other appli-
ances. Appliances with mains plugs are
fitted with a safety-tested mains cable
for the respective country of use and
may only be connected to a correctly
earthed safety socket. Otherwise, there
is a risk of electric shock. Make sure that
the socket on the appliance or the do-
mestic safety socket is easily accessible
so that the mains cable can be un-
plugged from the socket in an emer-
gency or during servicing and mainte-
nance work.
Danger of electric shock!
Do not clean the hood with a steam
cleaner or water pressure cleaner. The
hood must be disconnected from the
power supply prior to cleaning
34

Installation instructions

Safety information
Installation, connection, commissioning
and repair work may only be carried out
by authorised technicians. This techni-
cian will be able to determine suitable
methods for securing the extractor hood
and providing the necessary exhaust air
ducting. The choice of attachment must
take account of the weight of the extrac-
tor hood and the load exerted on the
supporting surface. Note the extraction
values of the dowels supplied. Depend-
ing on the supporting surface, these
have the following values: Dowel Ø10
mm: concrete B25 9.4 kN brick Z20 5.2
KN solid calcium silicate KSV20 4.8 KN.
In the case of unstable supporting sur-
faces, a construction specialist such as
a structural engineer or architect must
be consulted to ensure the extractor
hood is safely installed.
Danger of injury!
The hood body may contain sharp
edges resulting from the manufacturing
process. For this reason, safety gloves
must be worn when installing it.
Safety information – Please observe
when extending/retracting the hood
Please make sure that there are no ob-
jects near (approx. 5 cm) the cover
plate / hood when extending/retracting it.
Any objects that drop into the hood shaft
can damage the hood!
Danger of electric shock
The mains voltage must correspond to
the details indicated on the type plate.
This plate is located inside the hood
near the filters. Only connect the extrac-
tor hood to a properly installed safety