Start

PROCEDURE
Open the fuel tap.
1. Turn the engines gas control to "start".
2. Turn the decompression lever down, (it returns automatically after start)
3. Pull the engine's starting cord slowly until you feel resistance. Thereafter pull in one long
draw. Never let the starting cord run back by itself, always follow it with your hand.
4. Regulate the gas until the engine is running evenly.
5. Turn the key to the start position. If the engine does not start after 5 seconds, wait another
10 seconds and try again.
WARNING
Let go of the ignition key the moment the engine starts or else the engine's starter and battery will
be damaged.

Operation

NOTE
Please draw attention to the following during operation.
Exhaustion must not be black. If the exhaustion is black the load is too high or the engine
has not been adjusted correctly.
No incorrect noises and vibrations. If these appear turn off the engine and adjust it.
Contact your Power Line dealer.

Stop

PROCEDURE
Turn the gas control to a "low" position and let the engine run for a while.
Turn off the machine on the ignition switch.
Turn the fuel tap to the "off" position
If the machine is with electric-start, turn the key to the "off" position.