Mode 7
Function
Logging starts at defined time.
Logging stops when memory is full.
Setting
• Select "START UPON START TIME" as "RECORD
START CONDITION".
• Define start recording date and time in field "START
TIME".
Mode 8
Function
Logging starts at defined time.
Logging stops when button ENTER is pressed for few
seconds.
Setting
• Select "START UPON START TIME" as "RECORD
START CONDITION".
• Define start recording date and time in field "START
TIME".
• Select "STOP BUTTON" as "STOP STYLE".
Mode 9
Function
Logging starts at defined time.
Logging stops after PDF report generation.
Setting
• Select "START UPON START TIME" as "RECORD
START CONDITION".
• Define start recording date and time in field "START
TIME".
• Select "AFTER PDF CREATED" as "STOP STYLE".