AC Current Measurements (Auto Range)
Range
40 A
400 A
- Maximum Input Current: 500 A DC up to 60 seconds
- The given values are for frequencies from 40 to 400 Hz
- If the wire is not placed centrally in the jaws during current measure-
ment, the measuring error is about 1.5 %.
Resistance Measurements
Range
400 Ω
- Input Overload Protection is at 250 V AC/DC
Continuity Test
Off Load Voltage
-1.1 V up to -1.3 V
- Input Overload Protection is at 250 V AC/DC
* o. M. = of measuring value
** Dg. = Digit
Measuring Ranges
Resolution
0.01 A
0.1 A
Resolution
0.1 Ω
At a resistance under 40 Ohm you
will hear a signal sound.
26
Accuracy
<10 A ± 2 % o. M. ±10
Dg.
>10 A ± 2 % o. M. ±5 Dg.
Accuracy
± 1 % o. M. ±5 Dg.
Resistance