Part 1 - INSTALLATION INSTRUCTIONS

1 - GENERAL INFORMATION

This cooker hood is designed to be installed in the lower part of a cabinet placed
above a hotplate fitted against a wall. It can be used either in the extraction (ducted
to the outside) or in the recirculation mode (internal recycling). Before starting the
installation, consideration should be given to the difficulties to be found during
installation. The installation work must be undertaken by a qualified and
competent person in conformity to the rules concerning the evacuation of
contaminated air. The manufacturer disclaims all liability for any damage or
injury caused as a result of not following the instructions for installation
contained in the following text.

2 - SAFETY WARNINGS

2.1 - When used in the extraction mode, the cooker hood ducting must not be connected to
a flue which is used for exhausting fumes from appliances supplied with energy other
than electric, such as a central heating flue or water heating flue.
2.2 - Before connecting to the mains supply ensure that the mains voltage corresponds with
the voltage on the rating plate inside the hood.
2.3 - Connect the cooker hood to the mains via a bipolar switch which has 3 mm clearance
between the contacts.
2.4 - The appliance must be earthed.
2.5 - When installed, the hood must be positioned at least 65 cm above the hotplate.
2.6 - Never do flambé cooking under this cooker hood.
2.7 - Never leave frying pans unattended during use as overheated fat and oil may catch fire.
2.8 - Before carrying out any kind of maintenance or cleaning, disconnect the hood from the
mains supply.
2.9 - If the room where the cooker hood is to be used contains a fuel burning appliance such
as a central heating boiler then this must be of the room sealed or balanced flue type.
If other types of flue or appliance are fitted, ensure that there is an adequate supply of
air into the room. When the cooker hood is used in conjunction with appliances supplied
with energy other than electric, the negative pressure in the room must not exceed 0,04
mbar to prevent fumes being drawn back into the room by the cooker hood.

3 - INSTALLATION

This unit belongs to the category of semi-fitted hoods. The top portion is inserted
inside the overhead unit. After assembly, the pull-out undercarriage is positioned
outside the overhead unit and must be pulled out into a working position.

3.1 - Installation in the overhead unit

Using the template provided, cut the opening required to insert the top portion of the
hood in the base of the overhead unit. Open the pull-out undercarriage and remove
8