Variation D
Description: Power is supplied only once and it is only supplied to the first LEDs (as required)!
LEDs are connected to both ports via GROUND, DATA, possibly CLOCK, and V+ (6 A max.). This
variation is recommended for LEDs that use > 9 V, due to the expected voltage drop.
Alternative: Position the power supply between LEDs and NEBULA for LEDs with 5 V power supply.
Variation X1 – Port 1 or 2
Description: Power is supplied only once. It is supplied to NEBULA with 12 A max. and routed
through to the LEDs, which are connected only to Port 1 or only to Port 2 via GROUND, DATA,
possibly CLOCK, and V+ with 6 A max. load for the port.
Variation Y1 – Port 1 or 2
Description: Power is supplied to NEBULA over USB and supplied separately to the LEDs (as
required). The LEDs are connected only to Port 1 or only to Port 2 via GROUND, DATA, and possibly
CLOCK, but not via V+!