Docking
Eliminating heat spikes
To eliminate heat spikes in the heating system, a UKV tank is installed. Select diagonal connections (e.g. left up and
right down). Plug any connections that are not used.
Eliminating heat spikes as well as volume and flow increases
In cases where the system volume in the radiator circuit is below 20 l/kW (heat pump output at 7/45 °C) and/or the
radiator flow is choked uncontrolled, a UKV tank (120) is installed as a volume and flow increaser. Plug any connections
that are not used.
Note! These are outline diagrams. Actual installations must be planned according to applicable standards.