4 MOUNTING, TRANSPORT AND MOUNTING LOCATION

4
The installation of the transfer press must only be performed by suitably qualified personnel,
as the electrical connections must comply with local regulations.
EN
Before mounting the transfer press prepare a suitable mounting location.
Handle the package containing the transfer press with care and with the aid of suitable tools.
As the transfer press is heavy, the mounting should be performed by two people.
For the mounting location you need a stable table with a height of approximately 70 cm.
Fixing the unit's feet to the table top is a good way to increase the safety of the unit particularly
if the work table is mobile.
5

5 ELECTRICAL CONNECTION

The transfer press must be mounted in a room featuring a power supply system approved by
local authorities and complying with effective safety regulations for electric devices.
The available power supply lines must have a cross section sufficient for the transfer press's
energy demand of 2 kW, preferably in its own power circuit. The characteristic values of the
power supply system must comply with the characteristics of the heat transfer press. Please
check the values stated on the label.
The coloured conductor markings must be carefully complied with and the transfer press must
be earthed. Please refer to EN 60439 – 1 (CEI 17-13/1).
The power socket must have an electric protective earthing and a residual-current-operated
protective device (RCD) disconnecting the circuit if the residual current exceeds 30 mA.
Do not use cables with damaged insulation. It is inadvisable to use extension cords.
Remove the plug from the power socket before starting any maintenance or repair work, in
particular if it is necessary to open the box of the control panel or to perform work on the
heating elements.
The graphic symbol "High-Tension" signalises a serious danger and is attached on the box of
the control panel and on top of the heating elements. Switch off the master switch before
exchanging or removing heating elements.
6

6 CAP AND PLATE SET

For this model you may purchase easily interchangeable sets for converting the press:
A - Cap set with a bent heating plate and two supporting plates (cf. fig. a)
B - Plate set (cf. fig. b) consisting of :
- a supporting plate sized 15 x 38 cm e.g. for trouser legs or sleeves and
- a supporting plate sized 15 x 15 cm e.g. for shirt pockets
C - We'll be happy to produce plates in other sizes for you upon request.
22
TS-MONO Manual for use and maintenance
This manual is the property of SISER S.r.l., any even partial reproduction is forbidden
Mod. PRD 20/3 - Last updating 02/2018
fig. a - Cap Set twin