Technical Data

Specifications
Specification
Power requirements
Alarm inputs
Alarm outputs
Washer driver output
Communication
Push button
Cable Requirements
Power,
3-conductor
Washer output,
2-conductor
RS-485,
3-conductor shielded
Alarms,
Multi-conductor shielded
Cable Recommendations
The jacket of each selected cable should be suitable for outdoor use (UV-resistant, weather-
resistant, able to meet an operating temperature range of -40 to +60 °C (-40 to +140 °F)).
Recommended cable diameter
Stripping length
2014.09 | 1.3 | F.01U.305.934
Description
24 VAC ± 10%, 50/60 Hz, 1A
Four (4) normal dry contacts (selectable N.O./N.C.)
Two (2) monitored tamper alarm inputs, 2.2K ohm end-of-line
termination
Three (3) open collector outputs, 32 V, 150 mA
Dry contact relay, 250 V, 5 A
3-wire RS-485, half duplex
Momentary switch to activate washer relay
Connection
0.2 mm² - 0.5 mm² /
AWG 24 – 20
0.08 mm² - 0.2 mm² /
AWG 28 - 24
Installation Manual
Cable Gage
15 m (50 ft) with 0.2 mm² / AWG 24
120 m (400 ft) with 0.5 mm² / AWG
20
100 m (330 ft) with 0.08 mm² / AWG
28
6 - 10 mm (¼" – 3/8") / AWG 28 - 24
7 mm (0.25 in. approximately)
MIC Alarm-Washer Interface Unit