Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch MIC-ALM-WAS-24 Installationsanleitung Seite 16

Mic alarm-washer interface unit
Vorschau ausblenden Andere Handbücher für MIC-ALM-WAS-24:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
en | Installation
16
Pin
1
2
9. Verify power to the device.
The table below identifies the behavior of the LEDs on the PCBA when the device is working
as expected.
Red LED
Green LEDs
Yellow LED
10. Complete installation.
2014.09 | 1.3 | F.01U.305.934
Description / Function
Relay Normally Open
Relay Common
Check that the connections are secure.
Apply power to the device.
If desired, test the washer by pushing the red button labeled "PUMP ON" on the PCBA
(item 11).
The LED labeled "WASHER" on the PCBA (item 13) illuminates in response to telemetry
commands to turn on the washer. Note that the software in the camera prevents the
washer from running more than 10 seconds continuously to prevent emptying the washer
bottle.
LED
ON
Blinking
Blinking
Re-attach the enclosure lid.
Tighten the four (4) lid screws to 1.5 N m (9 - 13 in. lb) to ensure that the enclosure is
watertight.
If desired, slide the screw caps over the lid screws to protect the enclosure from
tampering.
Indicator
Power ON
Alarms active
RS-485 communications active
Installation Manual
MIC Alarm-Washer Interface Unit
Description
Bosch Security Systems

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis