Before Startup

Unpacking

Check the contents of the pack before
unpacking.
In case of transport damage inform ven-
dor immediately
 Draw the push-handle upwards until the
stop.
 Fix the push-handle using the enclosed
screws and tool.
Attaching the Accessories
 Mount the nozzle on the spray pipe
(markings on the adjustment ring at the
top).
 Connect ray tube to hand spray gun
 Fasten the high pressure hose to the
high pressure connection.

Start up

Warning
Risk of injury! Device, tubes, high pressure
hose and connections must be in faultless
condition. Otherwise, the appliance must
not be used.

Electrical connection

Danger
Danger of injury by electric shock.
The appliance may only be connected to al-
ternating current.
The appliance may only be connected to an
electrical supply which has been installed in
accordance with IEC 60364.
The voltage indicated on the type plate
must correspond to the voltage of the elec-
trical source.
The minimum fuse rating required at the
socket outlet is (see technical specifica-
tions).
The appliance should always be connected
to the electrical mains using a plug. It is for-
bidden to permanently connect the appli-
ance to the power supply. The plug is only
for mains separation.
Check the power cord with mains plug for
damage before every use. If the power cord
is damaged, please arrange immediately
for the exchange by an authorized custom-
er service or a skilled electrician.
The plug and coupling of the extension ca-
ble used must be watertight.
Use the extension cord that has an ade-
quate cross-section (see "Technical Data")
and unwind it fully from the cable drum.
Unsuitable electrical extension cables can
be hazardous. Only use electrical exten-
sion cables outdoors which have been ap-
proved and labelled for this purpose and
have an adequate cable cross-section:
For connection values, see type plate/tech-
nical data.
Water connection
Warning
Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
For connection values refer to technical
specifications
 Connect the supply hose (max length
7.5 m, minimum diameter 1/2") to the
water connection point of the machine
and at the water supply point (for e.g. a
tap).
Note
The supply hose is not included.
 Open the water supply.