Configuring the functions
Stagnation rinse:
DIP switch 5
Serves to rinse water supply lines in order to remove stagnant water that accumulates during
longer periods of disuse.
'ON' position:
Stagnation rinse is enabled.
'OFF' position:
Stagnation rinse function is disabled (default setting).
Time interval
Can be set from 3–48 h at DIP
switch 6 (see p. 4).
3 or 24 h
Intervall stagnation rinse:
DIP switch 6
You can select one of two predefined rinse intervals (3 h or 24 h, 24 h set by default).
'ON' position:
Stagnation rinse interval is set to 24 h.
'OFF' position:
Stagnation rinse interval is set to 3 s (default setting).
Automatic stagnation rinse
If the fitting has not been
used for the set period, a
stagnation rinse operation is
performed for 10 s.