on the machine.
Fault
Pump runs but does not
transport
Pump does not run or
suddenly comes to a
standstill during opera-
tions
22
To be connected to the suction hose meter
length. The backflow stop prevents the return
flow of the transported water and thus shortens
the re-suction time.
Durable metal/plastic construction. Suitable for
3/4" (19 mm) and 1" (25.4 mm) hoses.
Including hose clamp.
For the connection of 3/4" (19 mm) water hos-
es to pumps with G1 (33.3 mm) connection
threads. For increased water flow.
Particularly sturdy tap connection. Reducer al-
lows the connection to 2 thread sizes.
Recessed grips made of soft plastic ensure
easy handling. Universally useable for all com-
mon garden hoses.
Phthalate-free 3/4" garden hose for connecting
the pump with the application equipment.

Troubleshooting

Cause
Air in the pump
Suction area blocked
Suction hose or connection
adapter not screwed in cor-
rectly or completely.
Power supply interrupted
Thermal protection switch has
switched off the pump due to
over-heating
(Only with BP 4 Garden Set).
– 7
EN
Remedy
see chapter "Prepara-
tion" fig. B and and chap-
ter "Operations" fig. D
Pull out the mains plug
and clean the suction
area
Manually tighten the suc-
tion hose and the con-
nection adapter.
Check fuses and electri-
cal connections
Pull out the mains plug,
let the pump cool down,
clean the suction area,
prevent dry running

Quicklinks ausblenden: