Herunterladen Inhalt Inhalt Diese Seite drucken

Tools Required For Installation (Not Supplied) - Axair ulisse 13 A Bedienungsanweisungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DECLARATION OF CONFORMITY
This product is marked
– Low voltage no. 73/23 EEC and 93/68 EEC.
– Electromagnetic Compatibility no. 89/336 EEC, 92/31 EEC and 93/68 EEC.
This declaration will become void in case of misusage and/or from non observance though partial of Manufacturer's
installation and/or operating instructions.
THE EXTENSION KITS ARE SUPPLIED PRECHARGED
Before the installation, verify that they are fit for the unit.
UNIT
NARROW TUBE
MODEL
COOL/DRY/FAN
COOL/DRY/HEAT/FAN
POWER SUPPLY 220 / 240V ~ 50 Hz
GENERAL PRECAUTION
Check that the voltage and frequency of the power supply
G
match those required by the system.
Check the possibility to have the power line to the indoor unit
G
(ELECTRIC CABLE LENGTH 3 m).
Install a double - pole switch, protected by 10 A fuses of the
G
delayed type, upstream the electricity wall socket.
Make sure that the electrical installation is suitable to supply
G
continuosly current necessary for the air conditioner in addition
to that already used by other electric appliances (white goods,
lighting). See the max electric imput indicated on the name plate
positioned on the air conditioner.
Before connecting the air conditioner to a power socket,
G
make sure that the socket is provided with an earth
connection in compliance with local codes.
INSTALLATION SITE SELECTION
INDOOR UNIT
AVOID:
Positioning the indoor unit into rooms where it could be sprinkled
G
with water (i.e. laundries).
flammable gas or large amount of mist may be expected humidity
location.
Direct sunlight or near by heat source that may affect
G
performance of the unit.
furniture that obstruct air circulation.
DO:
Choose a position which allows proper ventilation in the room.
G
Verify respect of the minimum recommended maintenance
G
space.
OUTDOOR UNIT
AVOID:
Direct sunlight or area where hot air from exhaust fans investing
G
the unit.
DO:
Choose a place as cool as possible and well ventilated.
G

TOOLS REQUIRED FOR INSTALLATION (NOT SUPPLIED)

Phillips head screw driver
G
21 mm wrench
24 mm wrench
G
G
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
Synthetic oil HAB - Alkylbenzene type ex. ZERICE S EXXON, about 30 gr.
G
PVC pipe to insulate hole in the wall, external diameter 50 mm. of minimum length as for thickness wall.
G
as it satisfies Directives:
LARGE TUBE
OUTSIDE DIA.
OUTSIDE DIA.
6,35 mm
7,93 mm
6,35 mm
9,52 mm
Separately insulated
To install in areas where leakage of
G
Installing unit behind curtains or
G
Tape measure
Level
G
G
Hammer
Hacksaw
G
G
ACCESSORIES SUPPLIED WITH THE UNIT
CONNECTION EXTENSION KITS -
LENGHT OF 2 OR 4 m
ACCESSORY SUPPLIED ON REQUEST
* For heat pump version.
Hammer drill
Hole saw or key hole saw ø 50
G
G
Core bits 10 mm diameter drill bit.
G
1
PARTS
FIGURE
REMOTE
UNIT CONTROL
RAWL PLUG S X 5
SCREW 4,2x32
WASHER
PLASTIC PLUG
(MALE AND
FEMALE)
RAWL PLUG
S X 10
SCREW 7x65
WASHER
OUTDOOR UNIT
BASKET OR
SUPPORT
PARTI
FIGURA
EXTENSION KIT
FOR CONNEC-
TION TUBE
CONNECTIONS
PLASTIC BOX
RAWL PLUG
TAPPING SCREW
ø 3,5 x 45
CLAMP
19 mm wrench
G
(TO BE CONTINUED AT PAGE 2)
NR°
EG
1
2
2
2
2 + 2
2/3
2/3
2/3
1
1
1
3
3
2 + 8 *

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ulisse 10 aUlisse hla

Inhaltsverzeichnis