Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Lincoln Electric INVERTEC V205-T AC/DC Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für INVERTEC V205-T AC/DC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure
that all equipment in the area is compatible. This may require additional protection measures.
The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.

Technical Specifications

V205-T AC/DC:
Input Voltage
115/230 V ± 15%
Single Phase
Duty Cycle
(Based on a 10 min. period)
40% TIG 115/230 V
60% TIG 115/230 V
35% MMA 115/230 V
60% MMA 115/230 V
Welding Current Range
6-200 Amps
Fuse or Circuit Breaker Size
16 A Superlag
Height
385 mm
Operating Temperature
–20°C to +40°C
V305-T AC/DC:
Input Voltage
400 V ± 15%
Three Phase
Duty Cycle
(Based on a 10 min. period)
40%
60%
Welding Current Range
6-300 Amps
Fuse or Circuit Breaker Size
20 A Superlag
Height
500 mm
Operating Temperature
–20°C to +40°C
For any maintenance or repair operations it is recommended to contact the nearest technical service center or Lincoln
Electric. Maintenance or repairs performed by unauthorized service centers or personnel will null and void the
manufacturers warranty.
INPUT
Input Power at Rated Output
6.6 kW @ 40% Duty Cycle
RATED OUTPUT AT 40°C
Output Current
150/200 A
120/170 A
110/180 A
90/150 A
OUTPUT RANGE
RECOMMENDED INPUT CABLE AND FUSE SIZES
Type of Plug
SCHUKO 16A/250V
(Included with Machine)
PHYSICAL DIMENSIONS
Width
215 mm
INPUT
Input Power at Rated Output
11.8kW @ 40% Duty Cycle
RATED OUTPUT AT 40°C
Output Current
300 A
250 A
OUTPUT RANGE
RECOMMENDED INPUT CABLE AND FUSE SIZES
PHYSICAL DIMENSIONS
Width
275 mm
Maximum Open Circuit Voltage
Length
480 mm
Storage Temperature
-25°C to +55°C
Maximum Open Circuit Voltage
Input Power Cable
4 Conductor, 6 mm
Length
610 mm
Storage Temperature
-25°C to +55°C
9
Frequency
50/60 Hertz (Hz)
Output Voltage
16.0/18.0 Vdc
14.8/16.8 Vdc
24.4/27.2 Vdc
23.6/26.0 Vdc
53.7 Vdc
Input Power Cable
3 Conductor, 2.5 mm
Weight
17.6 Kg
Frequency
50/60 Hertz (Hz)
Output Voltage
32.0 Vdc
30.0 Vdc
81 Vdc
2
Weight
33 Kg
2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Invertec v305-t ac/dc

Inhaltsverzeichnis