Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Technical Data; Minimum Clearances - EOS Fin-Tec Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation

Technical data

Voltage: 400 V AC 3N 50 Hz
Power consumption: 4,5; 6,0; 7,5; 9,0 kW
according to model
Height: 780 mm at 180 mm fl oor clearance
Width: 375 mm,
depth: 360 mm
Filling capacity for stones: 15 kg
Stray current: max. 0,75 mA per kW heating
capacity
Sauna oven for use in family sauna
The sauna heating unit is VDE/GS certifi ed
for use with control unit type ECON A1,
ECON A2, ECON H2, EMOTEC B 6000,
EMOTEC DC 9000 or EMOTEC HCS
9003
The scope of delivery should include
1 sauna oven
1 accessory pack with
1 ea cable reel PG 16
3 ea self-tapping screws B 4.2 X 9.5
4 ea particle board screws
1 set of sauna stones, separately in cloth
bag
The sauna heating unit is intended only for
a supply voltage of 400 V AC 3N.
18

Minimum clearances

The minimum height of the sauna cabin must
be 1.90m on the inside.
The vertical clearance between the upper
edge of the sauna heating unit and the
sauna ceiling is at least 90 cm.
8 cm
1. Center wall mounting over the air intake
vent as in Illust. 2+ 3 and bolt onto cabin
wall with the particle board screws provi-
ded
Wall mounting
GB
Cabin wall
Oven safe-
ty grid
8 cm
37,5 cm
Illust. 1
Air
intake
vent
Illust. 2
Wall mounting
Air
intake
vent
Illust. 3

Werbung

Inhaltsverzeichnis
loading