Important notes

If assembled incorrectly, the sys
tem will present a fi re hazard. Please
read this installation guide thoroughly. It
is especially important to consider appli-
cable dimensions and observe the follo-
wing instructions:
• This device has not been designed for
being used by persons (including children)
that are physically or mentally handicap-
ped or have sensory disabilities. Moreover,
it is not allowed to use this device without
suffi cient experience and/or knowledge,
unless these persons will be supervised
by persons responsible for their security
or in case they have been instructed how
to use this device.
• Children are to be supervised in order to
make sure that they do not play with this
device.
The installation and connection of the
sauna heating unit, control unit and
other electrical equipment must be ac-
complished only by an expert. In this re-
gard it is especially important to meet the
required safety precautions in accordance
with VDE 0100 v. §49 DA/6 and VDE 0100
part 703/2006-2.
• The sauna heating and control units may
be installed only in sauna cabins made of
suitable, low resin and untreated material
(for example: Nordic pine)
• Only a sauna oven with the appropriate
heating capacity may be installed in the
sauna cabin (see Table 2).
• There should always be a provision for air
intake and exhaust vents in every sauna
cabin. The air intake vents must always
be aligned behind the sauna heating unit,
ca. 5 to 10 cm above the fl oor. Please use
the minimum dimensions of the air intake
and exhaust vents listed in Table 1.
• The exhaust vents must always be placed
towards the sauna heating unit diagonally
in the rear sauna wall, lower area. The
air intake and exhaust vents must not be
closed. Please observe the information
provided by your sauna cabin supplier.
• For the adjustment and control of the sau-
na heating unit, one of the control units
mentioned later must be used. This con-
trol unit must be attached to a suitable lo-
cation on the outer wall of the cabin, the
associated sensor housings in the interior
of the sauna cabin in accordance with the
installation guide which accompanies the
control units.
Caution: Covering and improperly
fi lled stone receptacles present a fi re
hazard.
Make certain that no objects have
been placed on the sauna heating
unit before each start-up.
Caution: High temperatures on the
heating unit during operation can
cause burns on contact.
• The sauna heating unit is not intended for
installation or placement in a niche under
the bench or under a roof slope.
• Do not start up operation of the sauna he-
ating unit with air intake vents closed.
• The cabin lighting with corresponding
mounting must be of a type that it is splash-
proof and able to withstand a surrounding
temperature of 140° C.
a VDE-certifi ed sauna lamp of 40 W ma-
ximum may be installed for use with the
sauna oven.
The sauna system (sauna hea-
ting unit, control unit and lighting etc.)
may be hard-wired to the power source
only by a locally certifi ed electrician. All
connecting lines laid on the inside of the
cabin must be able to withstand a surroun-
ding temperature of at least 140°C. For
practical purposes, a silicone line should
be used.
If singlewired cables are used
as connecting lines, they must be protec-
ted by fl exible metal tubing. The minimum
diameter of the connecting line and the
suitable cabin size in proportion to the po-