Example of a properly connected sauna system

Saunasteuergerät
control unit
L1 L2 L3 N
400 V AC 3N
Power supply capa-
city in kW
4,5
6,0
7,5
9,0
* or in accordance with the instructions of the
cabin manufacturer
suitable for
Power sup-
cabin size in m³
ply capacity
in kW
4,5
ca. 4 - 6
6,0
ca. 6 - 10
7,5
ca. 8 - 12
9,0
ca. 10 - 14
S1
U V W WB WM N
7,5 kW
U V W N PE
Minimum dimensions
of the air intake and
exhaust vents in cm
35 x 3
35 x 4
35 x 5
35 x 6
Table 1
Minimum diameters in mm² (Copper line)connection to 380-400V 3N
Power supply lead
wire, power supply
to control unit
5 x 2,5²
5 x 2,5²
5 x 2,5²
5 x 2,5²
Sensor
Caution! Always make certain to
include neutral conductor N clamp
4,5 kW
400 V AC 3N
U V W N PE
7,5 kW
400 V AC 3N
400 V AC 3N
U V W N
Oven connecting line
control unit to oven
5 x 1,5²
5 x 1,5²
5 x 1,5²
5 x 1,5²
GB
6 kW
400 V AC 3N
U V W N PE
9 kW
PE
max. 9 kW
N U V W
6 kW
400 V AC 3N
U V W N
PE
400 V AC 3N
U V W N
PE
Fuse pro-
ection in A
3 x 16
3 x 16
3 x 16
3 x 16
Table 2