Boiler mode operation
Current limits
Secure load
6

In case of fault

If your device does not function as intended, it is usually due to a small
detail. Please check whether or not the fault can be self-repaired
according to the following indicators. You will thereby avoid the costs
of an unnecessary repair service.
In normal operations, the LED "anode"
the LED "service"
is off.
If one of the two LEDs flashes, this indicates an "error condition".
In case of fault, do not disconnect the power supply line.
In order to possibly remedy the error condition oneself, there are
two procedures:
RESET: To begin with, please reset the device
proceed as follows:
Firstly, turn the dial
to the setting "●".
After that, press the "fast-heating" button
If the cause of the "error condition" does not exist directly after the
reset, the device will again return to its normal mode of function.
Otherwise the device will again indicate an "error condition".
Display (LED) Status
Anode
Service
Fast Heating
On
On
Flashing
On
On
Off
On
Flashing
Off
On/Off
Aus
Flashing
(see below)
TR5500T – 6 720 875 994 (2017/12)
1/N/PE~230 V
1/N/PE~230 V
1/N/PE~230 V
2/N/PE~230 V
2/N/PE~230 V
2/N/PE~230 V
is constantly lit,
RESET. To do this,
.
Cause / Fault
Internal electronic locked
The reservoir has heated with-
out water
Water temperature in reservoir
too hot
Internal electronic failure
Internal electronic failure
Anode fault
1 kW
1 kW 1/N/PE~230 V // 1 x min 10 A
2 kW
2 kW 1/N/PE~230 V // 1 x min 10 A
3 kW
3 kW 1/N/PE~230 V // 1 x min 16 A
1 kW
1 kW 2/N/PE~400 V // 2 x min 10 A
2 kW
2 kW 2/N/PE~400 V // 2 x min 10 A
3 kW
3 kW 2/N/PE~400 V // 2 x min 16 A
3
4
1
1. anode LED
2. service LED
3. fast-heating LED
4. fast-heating button
5. water temperature dial
Solution
Electronic board locked, wait 15mins and then reset.
Turn the device off, check the cause of the water shortage
(leakage, faulty water connection).
If the problem remains contact technician.
Reset, wait until the reservoir has cooled.
If the problem remains please contact technician.
Reset, if the problem remains please contact technician.
Reset, if the problem remains please contact technician.
Check that the reservoir is filled.
If the problem remains please contact technician.
In case of fault
1
2
e
3
5
Who
Technician
Technician
Technician
Technician
Technician
Technician
13