Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Lincoln Electric IDEALARC CV 420 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
machine.
Radio and/or television transmitters and receivers. Computers or computer controlled equipment.
Safety and control equipment for industrial processes. Equipment for calibration and measurement.
Personal medical devices like pacemakers and hearing aids.
Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure
that all equipment in the area is compatible. This may require additional protection measures.
The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.

Technical Specifications

IDEALARC CV 420 & CV 505
Input Voltage
230 / 400V ± 10%
Three Phase
Duty Cycle
(
Based on a 10 min. period
420:
60%
100%
505:
60%
100%
Welding Current Range
420:
505:
Fuse or Circuit Breaker Size
420:
505:
420:
420 (water version):
505:
505 (water version):
Operating Temperature
-10°C to +40°C
Input Power at Rated Output
420:
505:
RATED OUTPUT AT 40°C
)
30A - 420A
40A - 500A
RECOMMENDED INPUT CABLE AND FUSE SIZES
63A (for 230V) Superlag
32A (for 400V) Superlag
63A (for 230V) Superlag
40A (for 400V) Superlag
PHYSICAL DIMENSIONS
Height
870 mm
870 mm
870 mm
870 mm
INPUT
22 kVA @ 60% Duty Cycle
30 kVA @ 60% Duty Cycle
Output Current
420A
325A
500A
385A
OUTPUT RANGE
Maximum Open Circuit Voltage
420:
505:
420:
505:
Width
565 mm
700 mm
565 mm
700 mm
A-5
Frequency
50 Hertz (Hz)
Output Voltage
35.0 Vdc
30.3 Vdc
39.0 Vdc
33.3 Vdc
45 Vdc
48 Vdc
Input Power Cable
4 Conductor, 6mm
4 Conductor, 6mm
Length
1030 mm
1030 mm
1030 mm
1030 mm
Storage Temperature
-25°C to +55°C
2
2
Weight
134 kg
155 kg
149 kg
170 kg

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Idealarc cv 505

Inhaltsverzeichnis