Cross-sections
The D+ (alternator) is a signal cable and therefore 1-1.5
2
mm
is sufficient.
Connection to 12 V + and - must be done with a 10 mm
wire if the total wire length (+ and - wire together) is
maximally 12 m.
If longer wires are required a bigger cross-section cable
is needed.
Please consult a specialist, if you are not famil-
iar with the 12 V electrical system in your motor
home.
Interior light - bulb - change
If the bulb has to be replaced, proceed as follows:
1.
Remove the cover from the lamp body by pushing it
backwards.
2.
Remove the bulb.
3.
Put in a new bulb (12 V, max. 5 W).
Spare part number for bulb: 200 72 90-03.
4.
Push the lamp cover back in place.
TECHNICAL DATA
Overall dimensions, refrigerator
Height (incl. controls) ..................
2
Width ..........................................
Depth (incl. cooling unit)
with door .....................................
without door ................................
Recess dimensions
Height .........................................
Width ..........................................
Depth ..........................................
Capacity
Gross ..........................................
Net ..............................................
Frozen food compartment ..........
Weight (without packaging) ........
Electrical data
Input
* Energy consumption (in 24h) ...
LP gas data
Input, max. ..................................
* Energy consumption (in 24h) ...
Cooling medium: Ammonia
* Average consumption in 24 h at 25°C mean annual
ambient temperature according to ISO standards.
Subject to alteration without notice.
Wiring diagram RM 6505
230-240 volt ..................
12 volt ..................
RM 6505
1245 mm
525 mm
545 mm
495 mm
1248 mm
530 mm
510 mm
135 litres
124.5 litres
23.5 litres
44 kg
220 watt
175 watt
3 kWh
0.34 kW
300 g
19