Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SENTRON 3WL Funktionshandbuch Seite 60

Vorschau ausblenden Andere Handbücher für SENTRON 3WL:
Inhaltsverzeichnis

Werbung

Beschreibung der Bausteine
3.2 Treiberbaustein DRV_3WL
Anschluss (Parameter)
R_CUR_GRD_FLT_NA
MLFB
MLFB_QC
MLFB_OFF
MLFB_NA
RP_NORM_O
RP_NORM_O_QC
RP_REV_O
RP_REV_O_QC
PF_CAP_O
PF_CAP_O_QC
PF_IND_O
PF_IND_O_QC
T_RP_NORM_O
T_RP_NORM_O_QC
T_RP_REV_O
T_RP_REV_O_QC
T_PF_CAP_O
T_PF_CAP_O_QC
T_PF_IND_O
T_PF_IND_O_QC
OVER_FRQ_O
OVER_FRQ_O_QC
T_OVER_FRQ_O
T_OVER_FRQ_O_QC
UNDER_FRQ_O
UNDER_FRQ_O_QC
T_UNDER_FRQ_O
T_UNDER_FRQ_O_QC
CUR_THD_O
CUR_THD_O_QC
T_CUR_THD_O
T_CUR_THD_O_QC
VOLT_THD_O
VOLT_THD_O_QC
58
Kommentar
DR 129: Rated current ground fault
transformer Not Available
DR 129: Catalog number CB as upgraded
or changed by Cust. Or Service (text)
Quality Code of MLFB
DR 129: Catalog number CB as upgraded
or changed by Cust. Or Service (text) OFF
DR 129: Catalog number CB as upgraded
or changed by Cust. Or Service (text) Not
Available
DR 130: Real power in normal direction
Quality Code of RP_NORM_O
DR 130: Real power in reverse direction
Quality Code of RP_REV_O
DR 130: Power factor capacitive
Quality Code of PF_CAP_O
DR 130: Power factor inductive
Quality Code of PF_IND_O
DR 130: Delay time for Real power in
normal direction
Quality Code of T_RP_NORM_O
DR 130: Delay time for Real power in
reverse direction
Quality Code of T_RP_REV_O
DR 130: Delay time for Power factor
capacitive
Quality Code of T_PF_CAP_O
DR 130: Delay time for Power factor
inductive
Quality Code of T_PF_IND_O
DR 130: Over frequency
Quality Code of OVER_FRQ_O
DR 130: Delay time for Over frequency
Quality Code of T_OVER_FRQ_O
DR 130: Under frequency
Quality Code of UNDER_FRQ_O
DR 130: Delay time for Under frequency
Quality Code of T_UNDER_FRQ_O
DR 130: THD current
Quality Code of CUR_THD_O
DR 130: Delay time for THD current
Quality Code of T_CUR_THD_O
DR 130: THD voltage
Quality Code of VOLT_THD_O
Typ
Vor-
besetzung
BOOL
FALSE
STRING[18]
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
REAL
0.0
BYTE
0
Bausteinbibliothek SENTRON 3WL / 3VL für SIMATIC PCS 7
Funktionshandbuch, 11/2008, A5E02316905A-01
Art
B&B
O
x
O
x
O
O
x
O
x
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sentron 3vl

Inhaltsverzeichnis