Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SENTRON 3WL Funktionshandbuch Seite 36

Vorschau ausblenden Andere Handbücher für SENTRON 3WL:
Inhaltsverzeichnis

Werbung

Beschreibung der Bausteine
3.2 Treiberbaustein DRV_3WL
Anschluss (Parameter)
AP_I_OFF
AP_I_NA
T_RAP_REV_I
T_RAP_REV_I_QC
T_RAP_REV_I_OFF
T_RAP_REV_I_NA
T_AP_I
T_AP_I_QC
T_AP_I_OFF
T_AP_I_NA
CUR_OVER_I
CUR_OVER_I_QC
CUR_OVER_I_OFF
CUR_OVER_I_NA
CUR_GRD_I
CUR_GRD_I_QC
CUR_GRD_I_OFF
CUR_GRD_I_NA
CUR_N_I
CUR_N_I_QC
CUR_N_I_OFF
CUR_N_I_NA
CUR_DEM_I
CUR_DEM_I_QC
CUR_DEM_I_OFF
CUR_DEM_I_NA
T_CUR_OVER_I
T_CUR_OVER_I_QC
T_CUR_OVER_I_OFF
T_CUR_OVER_I_NA
T_CUR_GRD_I
T_CUR_GRD_I_QC
T_CUR_GRD_I_OFF
34
Kommentar
DR 130: Apparent power OFF
DR 130: Apparent power Not Available
DR 130: Delay time for Reactive power in
reverse direction
Quality Code of T_RAP_REV_I
DR 130: Delay time for Reactive power in
reverse direction OFF
DR 130: Delay time for Reactive power in
reverse direction Not Available
DR 130: Delay time for Apparent power
Quality Code of T_AP_I
DR 130: Delay time for Apparent power
OFF
DR 130: Delay time for Apparent power
Not Available
DR 130: Over current
Quality Code of CUR_OVER_I
DR 130: Over current OFF
DR 130: Over current Not Available
DR 130: Earth fault current
Quality Code of CUR_GRD_I
DR 130: Earth fault current OFF
DR 130: Earth fault current Not Available
DR 130: Over current N-phase
Quality Code of CUR_N_I
DR 130: Over current N-phase OFF
DR 130: Over current N-phase Not
Available
DR 130: Demand of the current
Quality Code of CUR_DEM_I
DR 130: Demand of the current OFF
DR 130: Demand of the current Not
Available
DR 130: Delay time for Over current
Quality Code of T_CUR_OVER_I
DR 130: Delay time for Over current OFF
DR 130: Delay time for Over current Not
Available
DR 130: Delay time for Over current
ground
Quality Code of T_CUR_GRD_I
DR 130: Delay time for Over current
ground OFF
Typ
Vor-
besetzung
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
Bausteinbibliothek SENTRON 3WL / 3VL für SIMATIC PCS 7
Funktionshandbuch, 11/2008, A5E02316905A-01
Art
B&B
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sentron 3vl

Inhaltsverzeichnis