Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SENTRON 3WL Funktionshandbuch Seite 32

Vorschau ausblenden Andere Handbücher für SENTRON 3WL:
Inhaltsverzeichnis

Werbung

Beschreibung der Bausteine
3.2 Treiberbaustein DRV_3WL
Anschluss (Parameter)
LIOP_SEL
AUT_L
AUTO_ON
AUTO_OFF
MSG_EVID1
MSG_EVID2
SUP_OVLD_WRN
SUP_SP_EXCEED
SUP_WRN
SUP_LD_SHED
RP_NORM_I
RP_NORM_I_QC
RP_NORM_I_OFF
RP_NORM_I_NA
RP_REV_I
RP_REV_I_QC
RP_REV_I_OFF
RP_REV_I_NA
PF_CAP_I
PF_CAP_I_QC
PF_CAP_I_OFF
PF_CAP_I_NA
PF_IND_I
PF_IND_I_QC
PF_IND_I_OFF
PF_IND_I_NA
T_RP_NORM_I
T_RP_NORM_I_QC
T_RP_NORM_I_OFF
T_RP_NORM_I_NA
T_RP_REV_I
T_RP_REV_I_QC
30
Kommentar
1 = Linking, 0 = Operator active
Linkable Input for MANUAL/AUTO mode
AUTO Mode: Switch off (open the main
contacts)
AUTO Mode: Switch on (close the main
contacts)
Message ID message block 1
Message ID message block 2
1 = Active message suppression
1 = Active message suppression
1 = Active message suppression
1 = Active message suppression
DR 130: Real power in normal direction
Quality Code of RP_NORM_I
DR 130: Real power in normal direction
OFF
DR 130: Real power in normal direction
Not Available
DR 130: Real power in reverse direction
Quality Code of RP_REV_I
DR 130: Real power in reverse direction
OFF
DR 130: Real power in reverse direction
Not Available
DR 130: Power factor capacitive
Quality Code of PF_CAP_I
DR 130: Power factor capacitive OFF
DR 130: Power factor capacitive Not
Available
DR 130: Power factor inductive
Quality Code of PF_IND_I
DR 130: Power factor inductive OFF
DR 130: Power factor inductive Not
Available
DR 130: Delay time for Real power in
normal direction
Quality Code of T_RP_NORM_I
DR 130: Delay time for Real power in
normal direction OFF
DR 130: Delay time for Real power in
normal direction Not Available
DR 130: Delay time for Real power in
reverse direction
Quality Code of T_RP_REV_I
Typ
Vor-
besetzung
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
DWORD
0
DWORD
0
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
Bausteinbibliothek SENTRON 3WL / 3VL für SIMATIC PCS 7
Funktionshandbuch, 11/2008, A5E02316905A-01
Art
B&B
I
I
I
I
I
I
I
x
I
x
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sentron 3vl

Inhaltsverzeichnis