Beschreibung der Bausteine
3.3 Treiberbaustein DRV_3VL
Anschluss (Parameter)
CUR_GRD_I_NA
CUR_N_I
CUR_N_I_QC
CUR_N_I_OFF
CUR_N_I_NA
CUR_DEM_I
CUR_DEM_I_QC
CUR_DEM_I_OFF
CUR_DEM_I_NA
T_CUR_OVER_I
T_CUR_OVER_I_QC
T_CUR_OVER_I_OFF
T_CUR_OVER_I_NA
T_CUR_GRD_I
T_CUR_GRD_I_QC
T_CUR_GRD_I_OFF
T_CUR_GRD_I_NA
T_CUR_N_I
T_CUR_N_I_QC
T_CUR_N_I_OFF
T_CUR_N_I_NA
UNBAL_CUR_I
UNBAL_CUR_I_QC
UNBAL_CUR_I_OFF
UNBAL_CUR_I_NA
T_UNBAL_CUR_I
T_UNBAL_CUR_I_QC
T_UNBAL_CUR_I_OFF
T_UNBAL_CUR_I_NA
T_CUR_DEM_I
T_CUR_DEM_I_QC
T_CUR_DEM_I_OFF
106
Kommentar
DR 130: Earth fault current Not Available
DR 130: Over current N-phase
Quality Code of CUR_N_I
DR 130: Over current N-phase OFF
DR 130: Over current N-phase Not Available
DR 130: Demand of the current
Quality Code of CUR_DEM_I
DR 130: Demand of the current OFF
DR 130: Demand of the current Not Available BOOL
DR 130: Delay time for Over current
Quality Code of T_CUR_OVER_I
DR 130: Delay time for Over current OFF
DR 130: Delay time for Over current Not
Available
DR 130: Delay time for Over current ground
Quality Code of T_CUR_GRD_I
DR 130: Delay time for Over current ground
OFF
DR 130: Delay time for Over current ground
Not Available
DR 130: Delay time for Over current N-phase REAL
Quality Code of T_CUR_N_I
DR 130: Delay time for Over current N-phase
OFF
DR 130: Delay time for Over current N-phase
Not Available
DR 130: Phase unbalance current
Quality Code of UNBAL_CUR_I
DR 130: Phase unbalance current OFF
DR 130: Phase unbalance current Not
Available
DR 130: Delay time for Phase unbalance
current
Quality Code of T_UNBAL_CUR_I
DR 130: Delay time for Phase unbalance
current OFF
DR 130: Delay time for Phase unbalance
current Not Available
DR 130: Delay time for demand of the
current
Quality Code of T_CUR_DEM_I
DR 130: Delay time for demand of the
current OFF
Typ
Vor-
besetzung
BOOL
TRUE
REAL
0.0
BYTE
16#80
BOOL
FALSE
BOOL
TRUE
REAL
0.0
BYTE
16#80
BOOL
FALSE
TRUE
REAL
0.0
BYTE
16#80
BOOL
FALSE
BOOL
TRUE
REAL
0.0
BYTE
16#80
BOOL
FALSE
BOOL
TRUE
0.0
BYTE
16#80
BOOL
FALSE
BOOL
TRUE
REAL
0.0
BYTE
16#80
BOOL
FALSE
BOOL
TRUE
REAL
0.0
BYTE
16#80
BOOL
FALSE
BOOL
TRUE
REAL
0.0
BYTE
16#80
BOOL
FALSE
Bausteinbibliothek SENTRON 3WL / 3VL für SIMATIC PCS 7
Funktionshandbuch, 11/2008, A5E02316905A-01
Art
B&B
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x
I
x
I
x
I
I
x

Quicklinks ausblenden: