Beschreibung der Bausteine
3.2 Treiberbaustein DRV_3WL
Anschluss (Parameter)
PF_L3_NA
FRQ
FRQ_QC
FRQ_NA
THD_CUR94
THD_CUR94_QC
THD_CUR94_NA
THD_VOLT
THD_VOLT_QC
THD_VOLT_NA
FORM_F
FORM_F_QC
FORM_F_NA
CREST_F
CREST_F_QC
CREST_F_NA
TMP_CUB
TMP_CUB_QC
TMP_CUB_NA
TMP_MSAE
TMP_MSAE_QC
TMP_MSAE_NA
C_VT_YD
C_VT_YD_QC
C_VT_YD_OFF
C_VT_YD_NA
T_VOLT_T
T_VOLT_T_QC
T_VOLT_T_OFF
T_VOLT_T_NA
ROV_PH_PH
ROV_PH_PH_QC
ROV_PH_PH_OFF
46
Kommentar
DR 94: Power factor in phase L3 Not
Available
DR 94: Frequency
Quality Code of FRQ
DR 94: Frequency Not Available
DR 94: THD of the current
Quality Code of THD_CUR94
DR 94: THD of the current Not Available
DR 94: THD of the voltage
Quality Code of THD_VOLT
DR 94: THD of the voltage Not Available
DR 94: Form factor
Quality Code of FORM_F
DR 94: Form factor Not Available
DR 94: Crest factor
Quality Code of CREST_F
DR 94: Crest factor Not Available
DR 94: Temperature in the cubicle (det. in
the COM15)
Quality Code of TMP_CUB
DR 94: Temperature in the cubicle (det. in
the COM15) Not Available
DR 94: Temperature in the circuit breaker
(det. in BSS)
Quality Code of TMP_MSAE
DR 94: Temperature in the circuit breaker
(det. in BSS) Not Available
DR128: Primary connection of the voltage
transformer Ypsilon or Delta
Quality Code of C_VT_YD
DR 128: Primary connection of the voltage
transformer Ypsilon or Delta OFF
DR 128: Primary connection of the voltage
transformer Ypsilon or Delta Not Available
DR 128: Typ Voltagetransformer
Quality Code of T_VOLT_T
DR 128: Typ Voltagetransformer OFF
DR 128: Typ Voltagetransformer Not
Available
DR 128: Rated operational voltage
(Phase2Phase)
Quality Code of ROV_PH_PH
DR 128: Rated operational voltage
(Phase2Phase) OFF
Typ
Vor-
besetzung
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
BOOL
FALSE
BYTE
0
BOOL
FALSE
BOOL
FALSE
BYTE
0
BYTE
0
BOOL
FALSE
BOOL
FALSE
REAL
0.0
BYTE
0
BOOL
FALSE
Bausteinbibliothek SENTRON 3WL / 3VL für SIMATIC PCS 7
Funktionshandbuch, 11/2008, A5E02316905A-01
Art
B&B
O
x
O
x
O
O
x
O
x
O
O
x
O
x
O
O
x
O
x
O
O
x
O
x
O
O
x
O
x
O
O
x
O
x
O
O
x
O
x
O
O
x
O
x
O
x
O
O
x
O
x
O
x
O
O
x