Safety Precautions

Danger of Injuries
During drilling operations on walls and ceilings, the Metal Core Drilling Machine
must be safeguarded with the included safety belt (f). The magnetic adhesion is
not maintained in case of a failure of circuit.
The cut core will be ejected automatically by the ejector pin. Danger of accident!
The ejector pin could possibly break in case of improper use.
Only use undamaged power cord and extension cords and regularly check on
damages!
Power supply and voltage details at the device must correspond.
Personal protection equipment
When working with this device, wear the following protection equipment:
Safety goggles, appropriate footwear, ear protection, hair net (for long hair),
possibly also apron and safety helmet.

Precautions of use

The place of installation for the magnet foot must be clean and rustfree. Remove
lacquer- and filler.
For non-magnetizable materials, please use the ROTABEST Vacubest (Prod.-No.
18150).
Do not execute any electric welding on the workpiece, on which the Metal Core
Drilling Machine is used.
Prior to all operations, mount coolant unit (b).
Danger of injuries! Danger of an electric shock
For operations on walls and ceilings, we recommend cooling with our spray (ALFRA
BIO 2000, Prod.- No. 21010).