Herunterladen Inhalt Inhalt Diese Seite drucken

B) Opening/Closing The Flexible Current Sensor; Measuring Procedure - VOLTCRAFT 1386426 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

b) Opening/closing the flexible current sensor

Applying and removing the current clamp to or from non-isolated, dangerously live conductors is not
permitted.
The power circuit must be of zero-voltage state before applying or removing the flexible sensor.
Use personal protective equipment.
• In order to open the flexible current sensor (5),
first turn the rotary lock (6) anticlockwise by 90º.
• Pull the end of the flexible current sensor out
from the rotary lock.
• Embrace the conductor to be measured with the
flexible sensor and then guide it back into the
rotary lock.
• Turn the rotary lock clockwise by 90º. The arrow
markings on the rotary lock and on the housing
must be aligned with each other.
Only embrace one single conductor with the flexible
current sensor, as the currents could otherwise
override each other and cause wrong readings.
Never touch the product above the grip
area (4) / above the display during
measurement. The product is very sensitive
and could display incorrect readings in such
a case.
c) Measuring procedure
The measuring range of the product is of max. 3000 A. When measuring more than 3000 A, the display will
show "OL".
• Switch on the product by pressing and holding the
• The product immediately starts measuring the alternating current of the electric conductor embraced by the
flexible current sensor (5); the reading appears in the display (1).
• Briefly press the /Hold button to freeze the displayed value. "HOLD" appears in the left corner of the display.
• Briefly press the /Hold button again in order for the display (1) to show the current value again; "HOLD" will
disappear.
For better readability, press the light button (3) to switch the background light of the display on or off.
• Switch off the product by pressing the
20
/Hold button (2) for 2 seconds.
/Hold button for 2 seconds.

Werbung